Build version 2.6.1.x (Windows) / 2.6.1.x (Mac)
Coil Pro Stabilization Filter
Added a new pose-balancing filter that improves overall body posture by better aligning glove and suit tracking data. The filter is available for both live and recorded clips, with the most noticeable improvements appearing in recorded clips. When using the Coil Pro with a Smartsuit Pro, the filter is enabled automatically and can be disabled from the right-side panel.
We hope you enjoy and as always, remember to share your thoughts and impressions.
- Discord (general feedback, issues, etc.)
New Features - Improvements
- Smartgloves II: Press and hold the button on the glove to remotely trigger a calibration. This feature is supported only when the gloves are connected in standalone mode and not through a Glove Ready suit.
- Smartgloves II: Button actions now respect the configured recording delay, calibration delay, and the Auto-enter Clip View after a recording stops setting.
- Livestreaming: Added a livestreaming target for Optitrack's Motive. Only glove streaming is supported.
Fixed Issues
- Fixed several issues affecting sensor firmware installation on Smartsuit Pro devices.
- Fixed sensor firmware installation failures when devices were in a full bootloader state.
- Fixed multiple issues related to device setup and firmware upgrades.
- Fixed limitations affecting the number of devices that could be connected via USB simultaneously.
- Fixed a rare issue where scenes containing multi-actor clips would fail to load if one actor's motion data was missing.
- Fixed an issue where Studio could not load the selected team after a software update.
- Fixed an issue where the devices would not reconnect after starting a debug device recording.
Known Issues
- If you get a "device driver stopped with exit code 0" on Studio startup:
- Close Studio
- Go to %USERPROFILE%\AppData\LocalLow\Rokoko Electronics\Rokoko Studio\Production\logs\device_service and delete the persisted_settings.json file
- Re run Studio
- In rare cases, a firmware installation may report a failure at the end of the upgrade process. This is a false negative, the firmware has been installed successfully. If this occurs, reboot the device and it should initialize normally.
- Firmware installations may fail if other devices are already connected to Studio via Wi-Fi. During upgrades, ensure only the target device is connected.
See Rokoko Studio - Known Issues for an overview of all known issues, and Coil Pro - Known Issues for those specifically related to Coil Pro.